Showing 37–48 of 155 results
EldonCard Single-Person Blood Typing Kit (ABO and RhD)
9.50€
| NSN | 6550-22-627-4454 |
|---|---|
| Manufacturer | Eldon Biologicals A/S |
| Model | EldonCard Single-Person Kit |
| Country of origin | Denmark |
| Product type | Medical device |
| Features | ABO and RhD determination; dried reagents on the card; no laboratory equipment required; result can be preserved on the card; single-person kit. |
| Certifications | FDA cleared, CE marked, gamintojas nurodo ISO certification. |
| Shelf Life | 24 months / 2 years from the date of manufacture when stored at 5–37 °C. |
| Use | Personal blood typing before military service, travel, training exercises, or blood donation. |
| Warnings | The result is intended for personal informational use. Before a blood transfusion, the blood group must be determined by an accredited laboratory. Dispose of the used lancet as sharps waste. |
| Storage | Store in a dry place at room temperature. Protect from direct sunlight. |
| Color | Balta |
| Contents | 1 × EldonCard® 2511 blood typing card, 1 × sterile single-use safety lancet, 1 × pipette/dropper, 1 × alcohol swab, 4 × EldonSticks, 1 × EldonFoil protective film, 1 × illustrated instructions for use. |
Electrical Burn, Large
90.00€
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW011-L |
| Country of origin | USA |
| Product type | Teaching aid |
| Features | Self-adhesive backing – no additional adhesive required; transferable from one actor or model to another; reusable; can be washed with warm, soapy water to restore its adhesive properties. |
| Sterility | Non-sterile |
| Use | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Contents | 1 wound imitation |
Electrical Burn, Medium
80.00€
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW008-L |
| Country of origin | USA |
| Product type | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Use | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Product Dimensions | 8,9 × 15,9 cm (3,5 × 6,25″) |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Contents | 1 wound imitation |
EOlife X Ventilation Feedback Device for Training
1,340.50€
| Manufacturer | Archeon Medical |
|---|---|
| Model | EOlife X, training version |
| Country of origin | France |
| Product type | Teaching aid |
| Features | Measures Vi, Vt, and ventilation rate in real time; Monitored mode with visual feedback; data export via Bluetooth to EOlife Connect; compatible with adult and paediatric manikins (from 1 year of age); algorithms based on ERC and US guidelines. |
| Certifications | Developed in accordance with ERC and AHA resuscitation guidelines. |
| Sterility | Non-sterile |
| Shelf Life | 5 years. |
| Use | Non reusable. Manual ventilation training and assessment in medical courses, simulation centres, and emergency service training programmes. |
| Warnings | FOR TRAINING USE ONLY. Do not use on patients. A separate EOlife model is intended for clinical use. |
| Storage | Store in a dry place in the original box; charge according to the manufacturer’s instructions. |
| Product Dimensions | 130 × 75 × 30 mm |
| Color | Juoda |
| Contents | 1 × EOlife X įrenginys, 1 × FlowSense X daugkartinis mokomasis jutiklis, 1 × keičiama baterija, 1 × įkroviklis su adapteriais, 1 × transportavimo dėklas, naudojimo instrukcija. |
Eye Shield for Ocular Trauma Protection
2.00€
| Manufacturer | SCILO |
|---|---|
| Model | Eye Shield for Ocular Trauma Protection |
| Country of origin | Germany |
| Product type | Medical device |
| Features | Transparent rigid protective eye shield; 80 × 65 mm; 9 ventilation holes; anatomical shape; reinforced and rounded edges; lightweight plastic construction; allows observation of the eye area without removing the shield; single-use; non-sterile; Class I medical device; CE marked. |
| Certifications | CE marked; Medical Device (MD) labelling. |
| Sterility | Non-sterile. |
| Product Dimensions | Dimensions: 80 × 65 mm (8 × 6.5 cm) Ventilation holes: 9. |
| Use | Penetrating and blunt eye injuries, foreign objects in the eye, and eye protection during evacuation. |
| Warnings | In cases of penetrating eye injury, do not apply pressure to the eye, remove any embedded foreign object, or irrigate the eye. Urgent ophthalmological care is required. |
| Storage | Store in a dry place in the original packaging. |
| Color | Skaidri |
| Contents | 1 × AO-600 transparent protective eye shield with 9 ventilation holes. |
Fire Cloak EV Fire Blanket for Electric Vehicles
1,400.00€
| Manufacturer | Prosol UK Sales & Distribution Ltd |
|---|---|
| Model | Fire Cloak EV Fire Blanket for Electric Vehicles |
| Country of origin | United Kingdom |
| Product type | Fire safety measure |
| Features | Fire Cloak EV is a professional fire containment blanket designed for electric and hybrid vehicles. It helps limit the spread of flames, heat, and smoke, protecting the surrounding area until emergency services arrive. Made from fire-resistant fibreglass with a silicone coating, it complies with BS 476 Class 0 requirements, has been tested in accordance with DIN SPEC 91489, and is supplied in a water-resistant transport bag. |
| Certifications | BS 476 Part 6 and Part 7 – Class 0 fire performance classification; DIN SPEC 91489 test report; technical testing by PZT GmbH. |
| Sterility | Non-sterile. |
| Shelf Life | 10 years when stored in accordance with the manufacturer’s recommendations. |
| Use | Isolation of electric and hybrid vehicle fires in car parks, workshops, ferries, and warehouses. Single-use. |
| Warnings | The blanket contains the fire but does not stop the lithium-ion thermal runaway – the battery can reignite. The fire service must be called. For use by trained personnel with appropriate protective equipment only. |
| Storage | Store dry in its designated container in an easily accessible location. |
| Product Dimensions | 8 × 6 m (48 m²) |
| Contents | 1 × Fire Cloak EV fire blanket, 1 × water-resistant transport and storage bag with handles. |
First Aid Pod Casualty Screen
130.00€
| Manufacturer | First Aid Pod Ltd. |
|---|---|
| Model | Casualty Privacy Screen |
| Country of origin | New Zealand |
| Product type | Ancillary aid |
| Features | First Aid Pod is a quick-deploy casualty privacy screen designed to provide privacy and protection while first aid is being administered. Its automatic pop-up construction allows it to be deployed within seconds, while the floorless design enables the screen to be positioned over the casualty without moving them. The water- and UV-resistant material provides protection from adverse weather conditions, while the DRSABCD reminder printed on the inner wall and carrying bag helps first aid providers follow the key sequence of resuscitation steps. Thanks to its compact size, lightweight design, and reusable construction, First Aid Pod is well suited for use by emergency medical services, at sporting events, in schools, public spaces, and workplaces. |
| Sterility | Non-sterile. |
| Use | Nukentėjusiojo privatumo ir orumo apsauga viešose vietose, renginiuose ir įvykių vietose prie kelio. |
| Warnings | Protection of casualty privacy and dignity in public places, at events, and at roadside incident scenes. |
| Storage | Store in a dry place in the original packaging. |
| Product Dimensions | Unfolded dimensions: 200 × 120 × 130 cm. |
| Color | Raudona |
| Contents | 1 × First Aid Pod privacy screen, 1 × carrying bag, 1 × emergency thermal blanket, 1 × CPR face shield, 4 × securing pegs. |
FoxSeal Occlusive Chest Seal (2-pack)
22.00€
| NSN | 6510-99-153-4041 |
|---|---|
| Manufacturer | Celox Medical (MedTrade Products) |
| Model | FoxSeal Occlusive Chest Seal, 2 pcs. / 2-Pack |
| Country of origin | USA |
| Product type | Medical device |
| Features | Non-vented occlusive chest seal; resealable adhesive surface; peel tabs; suitable for wounds up to 15 cm; adhesive performs at temperatures from −18 °C to +55 °C; 4 tear notches; 2 seals per pack. |
| Certifications | CE marked; EC Certificate CE 54955; GMDN 46424; UDI labelling. |
| Sterility | Sterile |
| Shelf Life | 5 years. |
| Use | Penetrating chest wounds up to 15 cm in length; management of pneumothorax risk. |
| Color | Skaidri |
| Contents | 2 chest seals. |
Fracture Wound
90.00€
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW013-L |
| Country of origin | USA |
| Product type | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Use | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Product Dimensions | Length: approximately 12.7 cm Width: approximately 9.5 cm |
| Contents | 1 wound imitation |
FSS fire extinguisher, professional use (50 s)
47.50€
| Manufacturer | ESP International S.r.l. |
|---|---|
| Model | Fire extinguisher, 50 s |
| Product type | Fire safety measure |
| Features | Approximately 50 seconds of discharge time; designed for professional use. |
| Certifications | CE |
| Shelf Life | 15 years. |
| Use | Single-use |
| Warnings | Before use, read the fire extinguisher instructions and verify the fire classes it is designed to extinguish. Using an extinguisher of the wrong class can increase the danger. The extinguisher must be inspected periodically in accordance with applicable regulations. |
| Storage | Store in a visible, easily accessible location; inspect in accordance with applicable regulatory requirements. |
| Product Dimensions | 25,9 × 3,3 cm |
| Contents | 1 × FSS50 aerosol extinguisher |
Gunshot Entry Wound, Large
50.00€
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW002-L |
| Country of origin | USA |
| Product type | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Product Dimensions | 6,35 × 6,35 cm (2,5 × 2,5″). |
| Use | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Contents | 1 wound imitation |
Gunshot Entry Wound, Small
50.00€
| Manufacturer | Techline Technologies, Inc. |
|---|---|
| Model | SW001-L |
| Country of origin | USA |
| Product type | Teaching aid |
| Features | Self-adhesive backing – no glue required; can be transferred from one casualty simulator to another; reusable; washable with warm soapy water to restore adhesion. |
| Sterility | Non-sterile |
| Product Dimensions | 5,7 × 5,7 cm (2,25 × 2,25″) |
| Use | Realistic first aid, tactical medicine, and mass casualty training scenarios with moulage volunteers. |
| Warnings | FOR TRAINING USE ONLY. Not intended for use on patients or actual wounds. Store separately from medical devices intended for clinical use to prevent accidental mix-ups. |
| Storage | Store in a dry place at room temperature, separately from medical devices intended for clinical use; protect from direct sunlight. |
| Contents | 1 wound imitation |